<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>16016</ErrorNumber>
<ErrorFamily>Image</ErrorFamily>
<ErrorMessage>
IMAGE: light level on detector too low
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Green</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The amount of light falling on the detector inside the head, used for stroke and DAOM calibration, is
unreasonably low.  This may indicate a head problem different from simply a gradual loss of throughput,
since that usually results in a "Can't flatten stroke" error.
</text></DescriptionText>
<DescriptionText><text>
There may be a problem with the laser, ranging from a blown fuse to an unrecoverable failure.
Also, the head's internal filter mechanism may be stuck.  Do not attempt to repair a head in the field
without explicit instructions from a head integrator.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Cancel this image, take the recorder offline, and reboot the recorder.  Contact service even if this clears up
the problem, since the Platesetter may need servicing.
</text></DescriptionText>
</OperatorAction>
<Cause>
Head is failing
</Cause>
<Cause>
Filter mechanism in head is stuck.
</Cause>
<Cause>
Laser malfunction.
</Cause>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:28 2008 PST
</Updated>
<Links>
</Links>
</Error>